Gas water heater vent clearances

0 votes
What is the required distance from water heater vent to window or door?
asked in Gas Water Heater by gordon-lewis (130 points)
edited by darekrudy
Share this question on your favorite network.

1 Answer

0 votes

Hi Gordon-Lewis,

You can follow this link - gas appliance chimney clearances - and click on the two pictures in that article. Natural draft water heater vent termination (or any other natural draft type gas burning appliance) must be located at least 8' from any vertical surface (it applies to doors and / or windows that might be installed in that surface) or it must extend at least 2 feet above the roof placed over that wall.

Just click "comment" below if you have any other questions.

answered by darekrudy (21,730 points)
...